NEW QUESTION # 15
What is the purpose of the Silicon-Based Hardware Root of Trust feature in Dell EMC PowerEdge
14G servers?
- A. Ensures that no unauthorized BIOS or firmware codes are run
- B. Ensures that the server has a valid Service Tag number
- C. Ensures that the server boots only when connected to a verified network
- D. Ensures that the installed operating system is authentic
Answer: A
NEW QUESTION # 16
A technician needs to deploy a server into production. The technician needs to verify that the firmware levels match corporate policy before putting the server on the business network.
Which two methods should the technician use to verify the firmware version of iDRAC and BIOS?
(Choose two.)
- A. Use the Lifecycle Controller and navigate to Firmware Update to view current versions
- B. Log into the iDRAC web interface to view Server Information
- C. Scroll through the menus on the LCD panel to view the BIOS and iDRAC firmware levels
- D. SSH into the iDRAC and run the command racadm system config to view current firmware
- E. Use the OMSA DVD that came with the server to view Current Drivers and Firmware
Answer: C,D
NEW QUESTION # 17
When does a customer require the Service Tag of the Dell EMC PowerEdge server?
- A. Activating the OS
- B. Obtaining warranty information
- C. First time accessing the BIOS
- D. First time logging in to iDRAC
Answer: B
NEW QUESTION # 18
Case Study 1
A company has several independent business units that operate globally. The company has consolidated its IT infrastructure services and operations. Common infrastructural services which include IPAM, DNS, NTP, DHCP, and SMTP have been consolidated.
The company has complimented its infrastructure development by investing in Dell EMC Isilon clusters to host its user's home and group directories and for compliance archival purposes required by individual business units. The IT operations are located in India and the United States with its primary data center facilities co-located between New York and Texas.
The company has a total of 60 AD forests:
- 1 main domain
- 55 domains have one-way trust relationships with the main domain
- An additional 4 domains do not have any trust relationship with no future plans of establishing trust relationships with the other domains.
Users of different AD domains use different FQDN to access their corresponding file services.
Additionally, the company does not plan to consolidate the AD domains and each domain uses a different IP subnet.
The users of the domains with no trust relationships have a compliance archival requirement. The company wants to all data to be replicated between New York and Texas.
How many tenant Access zones will be required?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: C
NEW QUESTION # 19
A Dell PowerEdge 16G server was ordered with the secure custom factory iDRAC password.
What is the result of selecting the Reset iDRAC configuration to default all option in the System Setup > iDRAC Settings?
- A. Preserves the iDRAC Network Settings and User accounts.
- B. At the next login to the iDRAC HI, a new password for the user root must be set.
- C. Resets the default username and password to the shipping password on the luggage tag.
Answer: C
Explanation:
Understanding the Impact of Resetting iDRAC Configuration to Default on a Dell PowerEdge 16G Server Server Management and Configuration Tools (14%)
* Define the function of the iDRAC, login procedures, licensing, and connection methods
* System Administration (18%)
* Configure BIOS, Storage, virtual media, networking, user access, lockdown mode, and group management Scenario Analysis
* Server Model: Dell PowerEdge 16G
* Ordered with: Secure custom factory iDRAC password
* Action: Selecting "Reset iDRAC configuration to default all" in the System Setup > iDRAC Settings Understanding iDRAC Passwords and Factory Settings
* Secure Custom Factory iDRAC Password:
* When a server is ordered with a secure custom factory iDRAC password, this password is unique to the server and is typically provided on theluggage tagattached to the server.
* Resetting iDRAC Configuration to Default:
* Impact:
* Resets all iDRAC settings to theirfactory defaults, including network settings, user accounts, and passwords.
* The iDRAC will revert to using the default credentials provided at the time of shipping.
* Password Reset:
* The default username is"root".
* The password is reset to theshipping password, which is the secure custom password provided on theluggage tag.
Explanation of Options
* Option A: "At the next login to the iDRAC UI, a new password for the user root must be set."
* Analysis:
* This behavior aligns with iDRAC versions that enforce password changes on first login, typically when a default password is used.
* However, when resetting to defaults, the iDRAC uses the shipping password, not prompting for a new password unless it is the default "calvin".
* Conclusion: Not the most accurate description.
* Option B: "Preserves the iDRAC Network Settings and User accounts."
* Analysis:
* Selecting "Reset iDRAC configuration to default all"does not preservenetwork settings or user accounts; it resets them to factory defaults.
* Conclusion: Incorrect.
* Option C: "Resets the default username and password to the shipping password on the luggage tag."
* Analysis:
* This is the correct outcome when performing a full iDRAC reset.
* The iDRAC reverts to the factory default settings, including the username and thesecure custom passwordprovided on the luggage tag.
* Conclusion:Correct Answer.
Dell Operate References
* Server Management and Configuration Tools (14%)
* Emphasizes understanding iDRAC functions, including resetting configurations and the implications for login procedures.
* System Administration (18%)
* Highlights the importance of managing user access and understanding the impact of resetting system settings.
Conclusion
When selecting "Reset iDRAC configuration to default all" on a Dell PowerEdge 16G server that was ordered with a secure custom factory iDRAC password, the iDRAC resets the default username and password to the shipping password provided on the luggage tag. This allows administrators to log in using the original secure password set at the factory.
NEW QUESTION # 20
What happens when the Hardware Root of Trust fails to validate the BIOS?
- A. The server continues running and logs a critical error in the system event log.
- B. Automated BIOS Recovery process recovers the BIOS from the DUP saved in the control panel.
- C. Boot Guard switches over to the backup BIOS and logs a warning in the system event log.
- D. The server shuts down and logs a critical error in the system event log.
Answer: D
NEW QUESTION # 21
A customer is attempting to install Windows Server 2022 on a Dell PowerEdge R740. However, Windows Server 2022 is not listed in the Available Operating Systems list in the Lifecycle Controller > OS Deployment Wizard.
How can the customer add Windows Server 2022 to the list?
- A. Update OS driver pack
- B. Change boot mode to UEFI
- C. Update BIOS
- D. Change installation source
Answer: A
NEW QUESTION # 22
After a disk rebuild operation, a technician needs to configure the system so that the rebuild process happens faster in the future, even at the expense of stowing users down.
How should the technician perform this task?
- A. Change the System Profile to Performance in the System BIOS Setting
- B. Change the Rebuild Rate in the System BIOS Settings
- C. Change the Rebuild Rate from me iDRAC GUI
- D. Change the System Profile 1o performance in the iDRAC GUI
Answer: C
NEW QUESTION # 23
Where is the Asset Tag located on the Dell EMC PowerEdge server?
- A. BIOS settings
- B. Dell manufacturing label
- C. Server chassis
- D. Pull-out information tab
Answer: A
NEW QUESTION # 24
A new Dell customer is ordering servers that have very specific firmware dependencies. Any replaced parts of the same type must match the replaced original part identically. The procedure must be as simple as possible with minimal risk.
What action should a technician take to accomplish this goal?
- A. Enable the Match Firmware of Replaced Part setting in the system BIOS
- B. Install and configure a repository manager
- C. Configure servers to access the remote firmware repository
- D. Enable the Collect System Inventory On Restart (CSIOR) attribute
Answer: D
NEW QUESTION # 25
A technician needs to update the iDRAC license on a PowerEdge R540 from Basic to Enterprise.
The server cannot be taken offline but the technician needs to have the additional features of the Enterprise license active as soon as possible.
How can the technician upgrade the license?
- A. Use the Lifecycle Controller, navigate to the Update and Rollback feature and upgrade to Enterprise
- B. The PowerEdge R540 can only be upgraded to iDRAC Express and not iDRAC Enterprise because it is an entry level server
- C. Use the iDRAC GUI to upgrade from Basic to Express, reboot the server and then use the iDRAC GUI to upgrade from Express to Enterprise
- D. Use the iDRAC GUI to upgrade from Basic to Enterprise
Answer: D
NEW QUESTION # 26
What is a key feature of Part Replacement in Lifecycle Controller?
- A. Automatically updates the configuration of the new part.
- B. What is a key feature of Part Replacement in Lifecycle Controller?
- C. Runs a parts replacement wizard.
- D. Automatically updates the server configuration database.
Answer: A
NEW QUESTION # 27
A technician configures a server then loads Windows 2016. The server then goes through testing.
Before the servers go live the technician asks another technician who has limited experience with servers to quickly check the settings to ensure that everything is operational.
The next day the server is rebooted and the operating system fails to load. No errors are displayed and the boot sequence is correct. Errors are found in the log entries.
What should be done to resolve this issue in the least amount of time?
- A. Reload the operating system
- B. Delete the RAID virtual disk then create a new virtual disk
- C. Check if the BIOS Boot Mode Setting is correct
- D. Check if the iDRAC Boot Mode Setting is correct
Answer: C
NEW QUESTION # 28
Exhibit.
What does the black strap on the power supply handle specify?
- A. Spare PSU
- B. PSU
- C. NAF
- D. RAF
Answer: C
Explanation:
Understanding the Black Strap on the Power Supply Handle
Server Components (26%)
* Identify power options and redundancy features, thermal features, and liquid cooling Explanation of Power Supply Straps Dell PowerEdge servers often useblack strapson power supply units (PSUs) to indicate certain attributes of the PSU. The color of the strap can help identify specific features or categories of the power supply.
What Does "NAF" Mean?
* NAFstands forNon-Redundant, Auto Failover.
* This indicates that the PSU is part of anon-redundant configuration, but it is capable of automatic failover in the case of power loss.
* This is typical in systems with multiple PSUs, where each PSU can take over if the other fails.
Why Not Other Options?
* Option A: PSU
* The strap does not indicate that the device is just a PSU; rather, it indicates a specific feature of the PSU.
* Option C: RAF
* RAFstands forRedundant Auto Failover, which is not the correct feature indicated by the black strap.
* Option D: Spare PSU
* The strap does not indicate that the PSU is a spare unit.
Conclusion
The black strap on the power supply handle indicates that the PSU isNAF (Non-Redundant, Auto Failover).
This means it is part of a non-redundant system but capable of automatic failover.
NEW QUESTION # 29
In addition to hashing, what algorithms are used by TPM?
- A. Random number generation
Symmetric key generation
Symmetric encryption/decryption - B. Sequential number generation
Symmetric key generation
Symmetric encryption/decryption - C. Sequential number generation
Asymmetric key generation
Asymmetric encryption/decryption - D. Random number generation
Asymmetric key generation
Asymmetric encryption/decryption
Answer: D
NEW QUESTION # 30
A technician updates firmware on all server components. After the updates have completed, testing of the NIC reveals a possible firmware problem.
What should the technician do to return the NIC to service?
- A. Replace the NIC using Part Replacement
- B. Enable Collect System Inventory on Restart
- C. Import the most recent Server Profile
- D. Perform Firmware Rollback
Answer: D
NEW QUESTION # 31
......
EMC D-PE-OE-23 Exam Syllabus Topics:
| Topic | Details |
|---|---|
| Topic 1 |
|
| Topic 2 |
|
| Topic 3 |
|
| Topic 4 |
|
| Topic 5 |
|
Pass EMC D-PE-OE-23 exam Dumps 100 Pass Guarantee With Latest Demo: https://www.latestcram.com/D-PE-OE-23-exam-cram-questions.html