NEW QUESTION # 36
Which three of the following data points does NetFlow use to confirm traffic is in the same flow? (Choose three.)
- A. L3 protocol
- B. port number
- C. IP address
- D. interface name
Answer: A,B,C
NEW QUESTION # 37
A network discovery profile for a network area completes with most devices discovered, except for a few SNMP enabled network devices. These undiscovered devices are verified to be operational and respond to SNMP queries.
What could be the cause?
- A. discovery timeout value is set too low
- B. SNMP community strings in profile are invalid
- C. no SNMP pollers match the device
- D. device MIB is not in SolarWinds' MIB database
Answer: B
NEW QUESTION # 38
Which three of the following steps should be taken to troubleshoot a 'test failed' result for SNMP nodes in hybrid cloud observability? (Choose three.)
- A. Verify the node can be pinged from the application server.
- B. Add remote site node and confirm firewall rules are configured to allow SNMP traffic.
- C. Confirm the use of SNMPv3 with authentication keys.
- D. Verify the SNMP service on the node has been restarted after changing the community string.
Answer: A,B,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
A). Ensuring that firewall rules allow SNMP traffic is essential, especially when monitoring remote site nodes.
C). Basic connectivity should be checked by pinging the node from the SolarWinds application server.
D). If the SNMP community string is changed, the SNMP service on the device must be restarted for the new configuration to take effect.
Option B is not required unless SNMPv3 is specifically being used, and even then, SNMPv2c and SNMPv1 are still widely supported and commonly used.
References:
NPM Administrator Guide: SNMP Troubleshooting Checklist
NEW QUESTION # 39
A node is being polled. The only data visible is response time and packet loss. Detailed statistics are needed.
How should this issue be resolved?
- A. switch polling method from SNMP to API
- B. switch polling method from SNMP to ICMP
- C. switch polling method from ICMP to SNMP
- D. switch polling method from WMI to SNMP
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
If only response time and packet loss are visible, the node is currently being polled via ICMP (ping), which does not provide detailed statistics like CPU, memory, or interface data. Switching the polling method to SNMP enables SolarWinds to gather detailed device metrics and statistics, as SNMP supports comprehensive monitoring.
Reference:
Network Performance Monitor Administrator Guide, "Enabling Detailed Polling with SNMP,"
"ICMP polling provides only basic availability and latency. Use SNMP polling for detailed statistics."
NEW QUESTION # 40
The unclassified traffic in the web console has been identified as MSSQL traffic. It is known as an application mapping that hybrid cloud observability maps by default. Which two of the following reasons explain why the traffic is showing as unclassified? (Choose two.)
- A. The version of MSSQL being used is not supported.
- B. The source or the destination port field is not present.
- C. A different port is being used.
- D. A firewall is blocking the traffic.
Answer: B,C
NEW QUESTION # 41
NetFlow and CBQoS monitoring can be disabled through web console settings. If NetFlow monitoring is disabled for a node or interface, the data collection is stopped. Which two of the following statements are true regarding disabling NetFlow monitoring? (Choose two.)
- A. historical data is retained within the database
- B. historical data is removed from the database
- C. enabling and disabling flow collection can result in gaps within NTA graphs
- D. enabling and disabling flow collection will not cause gaps within NTA graphs
Answer: A,C
NEW QUESTION # 42
Which three of the following devices are supported on SolarWinds' hybrid cloud observability IP flow monitor? (Choose three.)
- A. J-Flow
- B. nFlow
- C. sFlow
- D. IPF1X
Answer: A,C,D
NEW QUESTION # 43
Which switch model is supported in Network Insight?
- A. Cisco Nexus
- B. Brocade G620
- C. Juniper EX
- D. Meraki MX
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Network Insight in SolarWinds supports in-depth monitoring for certain advanced switch platforms.
According to the latest SolarWinds Network Performance Monitor Administrator Guide:
"Network Insight for Cisco Nexus provides advanced visibility into the health, configuration, and performance of Nexus switches. This includes inventory, configuration changes, interface health, VDCs, and more." Other switch families such as Brocade, Juniper, and Meraki are not currently supported by Network Insight.
References:
Network Performance Monitor Administrator Guide, Section: "Network Insight for Cisco Nexus"
NEW QUESTION # 44
To drill down into a log summary for a specific node, where in SolarWinds' platform can a user view these logs?
- A. Node Details Summary > Management > List Resources
- B. Alerts & Activity > Message Center
- C. My Dashboard > Logs > Log Viewer
- D. Node Details Summary > Management > Analyze Logs
Answer: D
NEW QUESTION # 45
What is the default amount of historical data needed for calculating capacity forecast?
- A. 7 to 30 days
- B. 7 to 180 day
- C. 1 to 90 days
- D. 1 to 30 days
Answer: B
NEW QUESTION # 46
What can be done to show the description of an object ID (OID)?
- A. Perform an SNMPwalk on the target device.
- B. Contact vendor to obtain the latest SNMPwalk.
- C. Update the MIB database via SolarWinds support.
- D. Download the latest OID.cfq from customer portal.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
In SolarWinds, the OID description is determined by the MIB database. If a particular OID description is missing or incorrect, the recommended action is to update the MIB database. This can be done by requesting the latest MIB database from SolarWinds support, which regularly releases updates to support new devices and OIDs.
Reference:
"If the description of an OID is not displayed, update the MIB database. SolarWinds support provides MIB database updates to include new device support and additional OID descriptions."
- (NPM Administrator Guide, SNMP and MIBs section)
NEW QUESTION # 47
If a NetFlow collector service is showing a "down" status, which two of the following steps are possible troubleshooting options? (Choose two.)
- A. Start or restart SolarWinds' NetFlow service from Orion service manager.
- B. Confirm the database connection is up and server has free resources.
- C. Delete and re-add NetFlow collector service.
- D. Start or restart SolarWinds' collector service.
Answer: A,B
NEW QUESTION # 48
Which statement related to flow alerts is true?
- A. based on custom SQL query
- B. have no trigger actions
- C. object of the alert selected from create a flow alert panel
- D. can be triggered even when NetFlow service is down
Answer: A
NEW QUESTION # 49
Network wide node and interface changes were recently made to several fields including names and IP addresses on nodes, captions, and aliases for their interfaces. Those changes are not updated in the hybrid cloud observability web console, even if a new polling is forced.
What should be done to resolve the issue?
- A. Run a rediscovery on both nodes and interfaces to refresh the data.
- B. Run a rediscovery on the node, which will also update the interfaces.
- C. Delete and re-add each of the nodes and their interfaces.
- D. Manually update the changed information in each poller.
Answer: B
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
A node rediscovery updates all node and interface information, including names, IP addresses, captions, and interface aliases. Running a rediscovery on the node ensures all related interface details are refreshed in the SolarWinds database and web console.
Reference:
"Running rediscovery on a node refreshes both the node's and its interfaces' properties, including names and IP addresses."
- (Network Performance Monitor Administrator Guide, Node Rediscovery section)QUESTION
NEW QUESTION # 50
What can be done to display the average CPU utilization of a node in a web console widget, if the device studio poller returns a table of multi-core CPU utilizations?
- A. Display the returned table of values in the web console widget and manually calculate the average.
- B. Contact the device vendor to provide an SNMP object ID (OID) for the average CPU utilization statistic.
- C. Select the add calculated value option and use the average function for returned values.
- D. Configure the web console widget to calculate the average of the returned table values.
Answer: C
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
When a device returns multi-core CPU statistics as a table, SolarWinds Device Studio allows you to use the
"Add Calculated Value" option and select the average function. This enables the web console widget to display the computed average CPU utilization automatically.
The documentation explains:
"For devices with multi-core CPUs, you can use the Add Calculated Value feature in the Device Studio to compute the average (or other statistical functions) of returned table values, which can then be visualized directly in widgets." References:
Network Performance Monitor Administrator Guide, "Device Studio Calculated Values" SolarWinds Success Center: "Averaging Table Poller Results"
NEW QUESTION # 51
Which two of the following technologies does device studio support? (Choose two.)
- A. baseline and thresholds
- B. throughput
- C. node details
- D. multi-CPU and memory
Answer: C,D
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Device Studio enables custom polling for multi-CPU and memory statistics and node details (such as chassis, serial number, and vendor-specific fields). Baselines/thresholds (A) are alert/report features, not Device Studio poller technologies. Throughput (D) is generally handled by standard interface polling, not Device Studio.
Reference:
Device Studio Admin Guide, "Technologies Supported by Device Studio,"
"Device Studio can be used for multi-CPU/memory polling and detailed node information."
NEW QUESTION # 52
After creating a new device studio poller that appears to be returning values on a test device, it is then applied to additional nodes. One of these new devices is not returning the statistics of the test node. Which two of the following reasons might be the cause of the issue? (Choose two.)
- A. devices have different firmware versions
- B. object IDs (QIDs) are not supported
- C. communication issue exists in new device
- D. new device needs to be rebooted
Answer: A,B
NEW QUESTION # 53
It is noted that the hardware health monitoring for a Cisco switch is generating false positives. It is verified that the alerted hardware issues are not occurring. What is causing the issue?
- A. Hardware sensors were incorrectly assigned to another switch.
- B. Restart SNMP on the device to refresh the hardware statistics.
- C. Modify the widget thresholds to filter out the false positives.
- D. MIB on the device is notthe preferred MIB that is beingpolled.
Answer: D
NEW QUESTION # 54
SNMP traps are being received from several devices. While most of the traps are normal, traps from one of the devices contain fields that are unreadable. The device is not being monitored in any other way. Which two of the following points should be checked? (Choose two.)
- A. Verify the device supports SNMP and is added as a node.
- B. Verify the device's MIBfile is in SolarWinds' MIB database.
- C. Verity the device supports hybrid cloud
- D. Verify the device is not usingSNMFV3 and is added as a node.
Answer: A,B
NEW QUESTION # 55
Flow data is not generating from a device in the web console. Wireshark was used to confirm the flows are being sent from the device to the poller and not blocked by the firewall. Why is the data not showing in the web console?
- A. flow monitoring was not enabled as device type in web console settings
- B. device is using IPv6 and HCO only supports IPv4
- C. missing source address field in flow configurations
- D. device is not monitored by hybrid cloud observability (HCO) features
Answer: C
NEW QUESTION # 56
What is the maximum number of resources that can be displayed in flow charts created by SolarWinds' platform views?
- A. 0
- B. 1
- C. 2
- D. 3
Answer: D
NEW QUESTION # 57
Which custom poller can display the poller results as a chart, gauge, or table?
- A. network insight
- B. universal device poller (UnDP)
- C. device studio poller
- D. hardware health
Answer: B
NEW QUESTION # 58
If an IP address group is hidden in IP address groups management, what impact will it have on the data?
- A. group will not be shown in charts or reports
- B. group will be shown in compliance reports
- C. group historical data will be deleted
- D. group will not be shown in IPAM
Answer: A
Explanation:
Comprehensive and Detailed Explanation From Exact Extract:
Hiding an IP address group in IPAM management means that group will not appear in dashboards, charts, or reports, but the underlying data and group definition remain intact and are not deleted.
Reference:
"When an IP address group is hidden, it will not appear in IPAM charts or reports, but historical data is retained unless deleted."
- (IP Address Manager Administrator Guide, IP Address Group Management section)
NEW QUESTION # 59
......
Study resources for the Valid Hybrid-Cloud-Observability-Network-Monitoring Braindumps: https://www.latestcram.com/Hybrid-Cloud-Observability-Network-Monitoring-exam-cram-questions.html
Hybrid-Cloud-Observability-Network-Monitoring Dumps are Available for Instant Access: https://drive.google.com/open?id=1UMFwH-yihMRIl6i-gB43s7TMVPwvW2ta